class="layout-aside-right paging-number">
본문 바로가기
반응형

전체 글118

소방 펌프 배선 요구사항(Fire Pump Wiring Requirements) 규정(법령, 법규, 기준, 규칙, 법, 근거, CODE, 코드) (A) 695.3 Power Source(s) for Electric Motor-Driven Fire Pumps. (3) Dedicated Feeder. A dedicated feeder shall be permitted where it is derived from a service connection as described in695.3(A)(1). (A) 695.3 전동기 구동 화재 펌프의 전원(3) 전용 피더 (Dedicated Feeder):전용 피더는 **695.3(A)(1)**에서 설명하는 서비스 연결(service connection)에서 유도된 경우에 허용된다. (B) 695.6 Power Wiring. (A) Supply Conductors. (2) Feeders. (d)(B) C.. 2025. 5. 4.
산업시설에서의 적절한 모터 외함 선택(Motor Enclosure Selection) - Class II, Division 2 관련 규정(법령, 법규, 기준, 규칙, 법, 근거, CODE, 코드) NEC ARTICLE 500 — HAZARDOUS (CLASSIFIED) LOCATIONS, CLASSES I, II, & III, DIVISIONS 1 & 2 📘 [NEC Article 500 — 위험 장소 (Hazardous Locations), Class I, II, III – Division 1 & 2] 500.5 Classifications of Locations. 🔶 500.5 위험 장소 분류 (C) Class II Locations. (C) Class II Locations (클래스 2 장소) Class II locations are those that are hazardous because of the presence of combustible dust. 👉 Class II 장소는.. 2025. 5. 1.
NEC에 따른 Class와 Division 구분/위험장소에 설치하는 전기기기 종류/Zone 방식 ✅ Class와 Division 구분1️⃣ Class (클래스: 위험물질 종류)Class I: "인화성 가스, 증기"로 인한 위험 (ex. 휘발유, 프로판가스)Class II: "가연성 먼지"로 인한 위험 (ex. 밀가루 가루, 알루미늄 분진)Class III: "섬유나 부스러기"로 인한 위험 (ex. 목재 가공현장의 섬유 먼지)👉 여기서 에어로졸은 "가스 형태"라서 Class I에 해당할 수 있죠.(하지만, 아까처럼 정상 상황에서 방출이 없으면 Unclassified!)2️⃣ Division (디비전: 위험 발생 빈도)Division 1 (디비전 1): 항상 또는 자주 위험 물질(가스, 먼지)이 존재하는 곳(예: 휘발유 주유 중인 장소, 공장 생산라인)Division 2 (디비전 2): 비정상 상황에.. 2025. 4. 29.
건설현장의 임시 전원 설치 허용 기간(Allowed Duration for Temporary Power Installation at a Construction Site) NEC ARTICLE 590 Temporary Installations 590.3 Time Constraints. ARTICLE 590 임시 설치 590.3 시간 제약 (Time Constraints)(A) During the Period of Construction. Temporary electric power and lighting installations shall be permitted during the period of construction, remodeling, maintenance, repair, or demolition of buildings, structures, equipment, or similar activities. (A) 공사 기간 동안건물, 구조물, 장비의 건설, 리모델.. 2025. 4. 27.
도체용 최소 정션박스 크기 산정 관련 규정(법령, 법규, 기준, 규칙, 법, 근거, CODE, 코드) (Determining Minimum Junction Box Size) ARTICLE 314 — OUTLET, DEVICE, PULL, & JUNCTION BOXES; CONDUIT BODIES; FITTINGS; & HANDHOLES 314.16 Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodies. (1) Standard Boxes. (A) Box Volume Calculations. The volumes of standard boxes that are not marked with their volume shall be as given in Table 314.16(A). Table 314.16(A) Metal Boxes 🔥 표(Table 314.16(A))에서 박스 고르는 .. 2025. 4. 27.
NEC에 따른 비상 전원 피더(Feeder) 회로 보호 요건 관련 규정(법령, 법규, 기준, 규칙, 법, 근거, CODE, 코드) ARTICLE 700 — EMERGENCY SYSTEMS 700.10 Wiring, Emergency System. (D) Fire Protection. Emergency systems shall meet the additional requirements in (D)(1) through (D)(3) in the following occupancies: (1) Assembly occupancies for not less than 1000 persons (2) Buildings above 23 m (75 ft) in height (3) Health care occupancies where persons are not capable of self preservation(4) Educational occupa.. 2025. 4. 26.
반응형