NEC 법규43

도체용 최소 정션박스 크기 산정 관련 규정(법령, 법규, 기준, 규칙, 법, 근거, CODE, 코드) (Determining Minimum Junction Box Size) ARTICLE 314 — OUTLET, DEVICE, PULL, & JUNCTION BOXES; CONDUIT BODIES; FITTINGS; & HANDHOLES 314.16 Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodies. (1) Standard Boxes. (A) Box Volume Calculations. The volumes of standard boxes that are not marked with their volume shall be as given in Table 314.16(A). Table 314.16(A) Metal Boxes 🔥 표(Table 314.16(A))에서 박스 고르는 .. 2025. 4. 27.
NEC에 따른 비상 전원 피더(Feeder) 회로 보호 요건 관련 규정(법령, 법규, 기준, 규칙, 법, 근거, CODE, 코드) ARTICLE 700 — EMERGENCY SYSTEMS 700.10 Wiring, Emergency System. (D) Fire Protection. Emergency systems shall meet the additional requirements in (D)(1) through (D)(3) in the following occupancies: (1) Assembly occupancies for not less than 1000 persons (2) Buildings above 23 m (75 ft) in height (3) Health care occupancies where persons are not capable of self preservation(4) Educational occupa.. 2025. 4. 26.
병렬 연결된 태양광 모듈(PV)의 전선 크기 산정 관련 규정(법령, 법규, 기준, 규칙, 법, 근거, CODE, 코드)(Conductor Sizing for Parallel PV Modules) NEC ARTICLE 690 — SOLAR PHOTOVOLTAIC (PV) SYSTEMS690.8 Circuit Sizing and Current.(A) Calculation of Maximum Circuit Current. The maximum current for the specific circuit shall be calculated in accordance with 690.8(A)(1) through (A)(6).🔹 (A) 회로의 최대 전류 계산📌 해당 회로의 최대 전류는 **690.8(A)(1)부터 (A)(6)**까지의 조항에 따라 계산되어야 한다.Informational Note: Where the requirements of 690.8(A)(1) and (B)(1) are b.. 2025. 4. 25.
병원 필수 전기 시스템 간선(branch) 중 필수 사항 관련 규정(법령, 법규, 기준, 규칙, 법, 근거, CODE, 코드) NEC ARTICLE 517 — HEALTH CARE FACILITIES517.31 Requirements for the Essential Electrical System.📘 NEC 517.31(A) 병원의 필수 전기 시스템 요건 (Requirements for the Essential Electrical System)(A) Separate Branches.Essential electrical systems for hospitals shall be comprised of three separate branches capable of supplying a limited amount of lighting and power service that is considered essential for life s.. 2025. 4. 23.
발전기 출력 단자에서 분배 장치까지의 전선 크기 산정 관련 규정(법령, 법규, 기준, 규칙, 법, 근거, CODE, 코드) NEC ARTICLE 445 — GENERATORS(A) General. The ampacity of the conductors from the generator output terminals to the first distribution device(s) containing overcurrent protection shall not be less than 115 percent of the nameplate current rating of the generator. 📘 NEC 445.13(A) 발전기 출력 전선의 암페어 용량 (Ampacity of Conductors)🔹 (A) 일반 규정 – General💡 **발전기 출력 단자에서 첫 번째 분배 장치(과전류 보호장치 포함)**까지의 전선은➡️ 발전.. 2025. 4. 22.
접지전극 관련 규정2(법령, 법규, 기준, 규칙, 법, 근거, CODE, 코드) 250.52 Grounding Electrodes.(B) Not Permitted for Use as Grounding Electrodes. The following systems and materials shall not be used as grounding electrodes:(1) Metal underground gas piping systems (2) Aluminum (3) The structures and structural reinforcing steel described in 680.26(B)(1) and (B)(2)🔹 1. 250.52(B) – 접지 전극으로 사용할 수 없는 것들 (Not Permitted)❌ 다음 시스템이나 재료는 접지 전극으로 사용할 수 없습니다:(1) 🔥 금속 지하.. 2025. 4. 20.